Online Electrochemical COD Analyzer

Facebook   Twitter   Delicious   Google   My EC21   Email this page   Report Item Inquire now
Online Electrochemical COD Analyzer

Click to enlarge image

 Model Number

HACA-2000


Electrochemical COD Analyzer

When electrochemically-active bacteria oxidize organic matter, they produce electrons. These electrons are transferred to electrodes and produce an electrical current. However, when wastewater containing toxic chemicals is introduced, it reduces the activity of electrochemically-active bacteria and interferes with the normal electron transfer system of the device. This interference will dramatically change the electrical current value. This changed electrical current, expressed as a BOD value, can measure toxicity.

Company A
Company B
KORBI
General specifications
Measurement Principle
Ozone oxidation electrochemical reduction method Electrochemical oxidization method Electrochemical oxidization method
Sensor
pH electrode, ozone sensor Lead oxidation electrode Modified metal combination electrode
Accuracy
- Error occurred by contamination of pH electrode
-Error occurred by ozone production
- Error occurred by contamination on lead
-coated electrode
-Not able to abrade or recover it
Minimize error rate of contamination because the modified metal combination electrode can be abraded or recovered
Maintenance
Cleaning of electrode
1 per week 1 per week 1 per 3 months
Replacement of measurement electrode
pH electrode/ 6 months 6 months 3 years
Replacement of reference electrode
Ozone sensor/ 1 year 1 year and 6 months 3 years
Environmental toxic substance
Produce lots of ozone gas None None
Field application
Pre-treatment system
A filter method/ if clogging occurs, replacement is necessary A filter method/ if clogging occurs, replacement is necessary UV irradiation method using a tangential flow method: no clogging or replacement necessary
Top water tubing
Required Required No
Distillation system
Required Required No
Air tank
Required No No
Manganate method or Chrome method
Not able to convert Not able to convert Able to convert
Time for Tech Support
2~3 months 2~3 months 2 days

Specification for Electrochemical COD Analyzer

Model
HACA-2000

Object of Measurement

COD (Chemical Oxygen Demand)

Type

Ammperometric analysis (Composite electrode)

Measurement Range

1~200ppm (Max. 100,000ppm)

Measurement Interval

1min-1Hr (adjustable)

Error

± 5 %

Display

Color LCD (6") touch screen

Printer

Thermal printer

Output Signal

Isolated 4-20mA, RS 232

Temperature & Humidity

0-35°C, less than 95% (RH)

Cleaning

Self-cleaning by flow injection

Revision

No voltage contact output (power, operation, malfunction)

Power Requirement

AC 110/220 V, 50/60Hz

Power Consumption

Max. 800VA

Dimension

600(W) x 1700(H) x 662(D)

Enclosure

Steel, IP5

Weight

150Kg

Sampler

Pretreatment system equipped with UV sterilization lamp is included